Troubleshooting 1. The lamp switch inputs can be checked using the GDS. 2. To check the input value of lamp switch, select option "Body Control Module". 3. To consult the present input/output value of ...
Specifications ItemsSpecificationsRated voltage5VLoadMax. 1mA (When head lamp lighting)Illuminations (LUX)501.42 ± 0.31V1002.63 ± 0.58V1503.84 ± 0.84V ...
High Voltage Shut-off Procedures Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • High voltage components: ...
Specification ItemSpecificationCapacitance (pF)850 ~ 1,150 ...