Specification |
Pressure [kPa (kgf/cm?, in H2O) | Output Voltage (V) |
-6.67 (-0.068, -26.8) | 0.5 |
0 | 2.5 |
+6.67 (0.068, 26.8) | 4.5 |
Description NVLD(Natural Vacuum Leakage Detection) is located between the canister and the fuel tank air filter. NVLD is to detect leaks equivalent to a 0.5 mm hole in the fuel tank, canister and hoses. ...
Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate Control Air Filter7. Climate Control Air Filter Cover8. Blower Upper Case9. Blower Lower Case10. PWM Blower Module11. Blower Motor ...
Description Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is ...