Specification |
Pressure [kPa (kgf/cm?, in H2O) | Output Voltage (V) |
-6.67 (-0.068, -26.8) | 0.5 |
0 | 2.5 |
+6.67 (0.068, 26.8) | 4.5 |
Description NVLD(Natural Vacuum Leakage Detection) is located between the canister and the fuel tank air filter. NVLD is to detect leaks equivalent to a 0.5 mm hole in the fuel tank, canister and hoses. ...
Specifications Direct control VFS [OD/C] Control type : Normal high type Control Pressure kpa(kgf/cm?, psi)500.14 ~ 9.81(5.1 ~ 0.1, 72.54 ~ 1.42)Current value (mA)50 ~ 850 Internal resistance (?)5.1 ...
Description NVLD(Natural Vacuum Leakage Detection) is located between the canister and the fuel tank air filter. NVLD is to detect leaks equivalent to a 0.5 mm hole in the fuel tank, canister and hoses. When the engine has been running, the temperature of the fuel in the fuel tank is raised slightly. ...