Waveform |
Specification Pressure (kPa)Output Voltage (V)20.00.79 46.71.84101.34.0 ...
Circuit Diagram ...
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals. 2. Inspect the voltage value whether it is sufficient to be regular value or not. Voltage = 0.00878835 * Pressure + 0.5[PSIA] 3. If the measured voltage value is not specification, replace ...
Inspection Lighting Switch Inspection With the multifunction switch in each position, make sure that continuity exists between the terminals below. If continuity is not as specified, replace the multi-function switch. Lighting Switch (Auto Light) Lighting Switch Dimmer And Passing Switch HU : Head lamp ...