Inspection |
1. |
After disconnecting the vapor hose from the PCV valve, remove the PCV valve. |
2. |
Reconnect the PCV valve to the vapor hose. |
3. |
Run the engine at idle, then put a finger over the open end
of the PCV valve and make sure that intake manifold vacuum can be felt.
|
4. |
If the vacuum is not felt inspect PCV operation, if operating correctly clean or replace the vapor hose. |
Schematic Diagram ...
Operation Principle ...
Self Diagnosis 1. Self-diagnosis process 2. How to read self-diagnostic code After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format ...