Inspection |
1. |
Remove the front door quadrant delta cover.
(Refer to the BD group - "Front door") |
2. |
Disconnect the power door mirror connector from the harness. |
3. |
Apply battery voltage to each terminal as shown in the table and verify that the mirror operates properly. Mirror Heater Inspection Turn Signal Lamp BSD Warning Lamp Mirror folding Inspection |
Inspection 1. Disconnect the negative (-) battery terminal. 2. Remove the front door trim panel. (Refer to the BD group - "Front door") 3. Disconnect the connector and remove the door mirror switch (A) ...
...
Specifications PumpPumping capacityAbout 6.46cc per one revolutionTypeInternal gearMotorType Brushless DC motor (3 phases)Torque Rated 1.5 N.mSpeed range100~2,500 rpm ...
Inspection 1. Connect the GDS on the Data Link Connector (DLC). 2. Measure the output voltage of the FTPS. Pressure [kPa (kgf/cm?, in H2O)Output Voltage (V)-6.67 (-0.068, -26.8)0.502.5+6.67 (0.068, 26.8)4.5 Removal 1. Turn the ignition switch OFF and disconnect the battery negative (-) terminal. 2. Lift ...