Description |
1. |
The photo sensor is located at the right of defrost nozzle. |
2. |
The photo sensor contains a photovoltaic (sensitive to
sunlight) diode. The solar radiation received by its light receiving
portion, generates an electromotive force in proportion to the amount of
radiation received which is transferred to the automatic temperature
control module so that the solar radiation compensation will be
performed. |
Inspection 1. Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals. 2. Inspect the voltage value whether it is sufficient to be regular value or not. Voltage ...
Inspection 1. Ignition "ON" 2. Using the scan tool. 3. Emit intensive light toward photo sensor using a lamp, and check the output voltage change. 4. The voltage will rise with higher intensive light and ...
High Voltage Shut-off Procedures Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • High voltage components: ...
Removal and Installation 1. Remove the engine cover. 2. Disconnect the battery negative terminal. Tightening torque: 4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft) 3. Disconnect the oxygen sensor connectors (A). 4. Remove the front muffler (A). Tightening torque: 39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ...