Description |
1. |
The intake actuator is located at the blower unit. |
2. |
It regulates the intake door by signal from control unit. |
3. |
Pressing the intake selection switch will shift between recirculation and fresh air modes. |
Component Location ...
Inspection 1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal ...
Components Location 1. Receiver2. TPMS sensor (FL)3. TPMS sensor (RL)4. TPMS sensor (RR)5. TPMS sensor (FR) ...
Inspection 1. Turn ignition switch OFF. 2. Remove the air duct (A). Tightening torque: 7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft) 3. Remove the air cleaner assembly. (1) Disconnect the breather hose (A). (2) Disconnect the air intake hose (B) and then remove the air cleaner assembly (C). Tightening ...