Description |
1. |
The intake actuator is located at the blower unit. |
2. |
It regulates the intake door by signal from control unit. |
3. |
Pressing the intake selection switch will shift between recirculation and fresh air modes. |
Component Location ...
Inspection 1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal ...
Specification [Throttle Position Sensor (TPS)] Throttle Angle(°)Output Voltage(V)TPS1TPS200.05.0100.484.52200.954.05301.433.57401.903.10502.382.62602.862.14703.331.67803.811.19904.290.711004.760.241055.00C.T (6 ~ 15°)0.29 ~ 0.714.29 ~ 4.71W.O.T (93 ~ 102°)4.43 ~ 4.860.14 ~ 0.57 ItemSensor Resistance(k?)TPS10.875 ...
Description Cluster Network Diagram ECMEngine Control ModuleHCUHybrid Control ModuleMCUMotor Control ModuleBMSBattery Management SystemTCMTransaxle Control ModuleEBSElectronic Brake SystemOPUOil Pump UnitMDPSMotor Driving Power SteeringLDCLow DC/DC ConverterFATCFull Automatic Temperature ControlEWPElectronic ...