Description |
Inspection 1. Turn ignition switch OFF. 2. Remove the air duct (A). Tightening torque: 7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft) 3. Remove the air cleaner assembly. (1) Disconnect the breather hose ...
Specifications Direct control VFS[35R/C] Control type : Normal high type Control Pressure kpa(kgf/cm?, psi)500.14 ~ 9.81(5.1 ~ 0.1, 72.54 ~ 1.42)Current value (mA)50 ~ 850 Internal resistance (?)5.1 ...
Inspection 1. Check the audio remote control switch for resistance between terminals in each switch position. [Trip + Reset] SwitchConnector terminalResistance (±5%)Reset3 - 5 (LH)5.54 k?Trip3 - 5 (LH)2.54 k? [Trip + Mute + Reset] SwitchConnector terminalResistance (±5%)Mute3-40 ?Trip (General option)2-52.55 ...
Troubleshooting SymptomsPossible CausesRemedyCoolant leakage • From the thermostat gasket Check the mounting bolts • Check the torque of the mounting bolts • Retighten the bolts and check leakage again. Check the gasket for damage • Check gasket or seal for damage • Replace gaskets and reuse ...