Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A).
|
3. |
Remove the air cleaner assembly.
|
4. |
Remove the solenoid valve connector (A). |
5. |
Measure resistance between signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to Hydraulic System - "Valve Body") |
Circuit Diagram ...
Description 35R clutch control solenoid valve(35R/C_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the 35R clutch. ...
Function 1. Push the A button lower of the rear view mirror to turn on the function of the compass mirror so that displays a sign of a direction on the small board in the upper-right side of the mirror. 2. Push the A button again to turn off its function. ...
Inspection with GDS Initialization and diagnosis sequence by using GDS equipment. Below content summarize the procedure for A/S using GDS. No.Procedure1Locate vehicle to flat plane2Tire check3IGN1 ON4Head lamp Low Beam ON5Connection with diagnostic tool6Initial command by diagnostic tool7Clear DTC Code8IGN1 ...