Specifications |
Temp.(°C)°F | Resistance (k?) |
(-40)-40 | 46.8 |
(-20)-4.0 | 15.6 |
(0)32.0 | 5.88 |
(20)68.0 | 2.51 |
(40)104.0 | 1.17 |
(60)140.0 | 0.59 |
(80)176.0 | 0.32 |
(100)212.0 | 0.18 |
(120)248.0 | 0.11 |
(140)284.0 | 0.07 |
(165)329.0 | 0.04 |
Description Transaxle oil temperature sensor monitors the automatic transaxle fluid''s temperature and conveys the readings to TCM. It is an NTC (Negative Thermal Coefficient) sensor whose resistance has ...
Circuit Diagram ...
Replacement 1. Discharge refrigerant from refrigeration system. 2. Replace faulty tube or hose. Cap the open fittings immediately to keep moisture or dirt out of the system. 3. Tighten joint of bolt or nut to specified torque. Connections should not be torque tighter than ...
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. BLOWER speedManual VoltageAuto Voltage13.4Auto Low(4.5V)24.64.5~5.535.95.6~6.747.26.8~7.758.37.8~8.969.59.0~10.1711.310.2~11.38B+? ...