Inspection |
1. |
Remove the front door trim.
(Refer to the BD group - "Front door") |
2. |
Remove the front door module. |
3. |
Disconnect the 7P connector from the actuator. |
4. |
Check actuator operation by connecting power and ground
according to the table. To prevent damage to the actuator, apply battery
voltage only momentarily. |
1. |
Remove the rear door trim.
(Refer to the BD group - "Rear door") |
2. |
Remove the rear door module. |
3. |
Disconnect the 7P connector from the actuator. |
4. |
Check actuator operation by connecting power and ground
according to the table. To prevent damage to the actuator, apply battery
voltage only momentarily. |
1. |
Remove the trunk lid trim panel.
(Refer to the BD group - "Trunk lid") |
2. |
Disconnect the 3P connector from the actuator. |
3. |
Check actuator operation by connecting power and ground
according to the table. To prevent damage to the actuator, apply battery
voltage only momentarily. |
1. |
Remove the front door trim panel.
(Refer to the BD group - "Front door") |
2. |
Remove the front door module. |
3. |
Disconnect the 7P connector from the actuator. |
4. |
Check for continuity between the terminals in each switch position when inserting the key into the door according to the table. |
1. |
Remove the rear door trim panel.
(Refer to the BD group - "Rear door") |
2. |
Remove the rear door module. |
3. |
Disconnect the 7P connector from the actuator. |
4. |
Check for continuity between the terminals in each switch position according to the table. |
1. |
Remove the trunk lid trim. |
2. |
Disconnect the 3P connector from the actuator. |
3. |
Check for continuity between the terminals in each switch position according to the table. |
Component Location 1. Driver power window switch2. Door lock switch3. BCM (Body Control Module)4. Front door lock actuator5. Rear door lock actuator6. Trunk lid open actuator7. SJB (Smart Junction Box) ...
Inspection Diagnosis With GDS 1. It will be able to diagnose defects of power door lock with GDS quickly. GDS can operates actuator forcefully, input/output value monitoring and self diagnosis. 2. Select ...
Removal • Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries. • Be sure to shut off the high voltage circuit according ...
Inspection Wrap tin foil around the end of the voltmeter test lead to prevent damaging the heater line. Apply finger pressure on the tin foil, moving the tin foil along the grid line to check for open circuits. 1. Turn on the defogger switch and use a voltmeter to measure the voltage of ...