Description |
Inspection 1. Check signal waveform of Input & output speed sensor using the GDS. Specification: Refer to "Signal Wave Form" section. Removal • Be sure to read and follow the “General ...
Specifications Type: Hall effect sensor Operation condition (°C)°F((-)40 ~ 150)) -104 ~ 302Air gap(mm)in.(0.25 ~ 1.9)0.00984 ~ 0.0748Output voltageHigh1.18 ~ 1.68Low0.59 ~ 0.84 ...
Description Ignition timing is controlled by the electronic control ignition timing system. The standard reference ignition timing data for the engine operating conditions are preprogrammed in the memory of the ECM (Engine Control Module). The engine operating conditions (speed, load, warm-up condition, ...
Description Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Catalytic Converter. It varies in accordance with the air/fuel ratio. The sensor must be hot in order to operate normally. To keep it hot, the sensor has a heater which is controlled ...