Kia Optima Hybrid: Air Conditioning System / Evaporator Temperature Sensor Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification
Evaporator core
temperature[°C(°F)]
Resistance[K?]
-10 / (14)
43.35
0 / (32)
27.62
10 / (50)
18.07
20 / (68)
12.11
30 / (86)
8.3
40 / (104)
5.81

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Loosen the mounting screw and then remove the crash pad lower cover (A).

3.
Remove the evaporator temperature sensor (A), by pulling it after rotating 90° in a counterclockwise direction.

4.
Installation is the reverse order of removal.
Evaporator Temperature Sensor Description and Operation

Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator freezing by excessive cooling ...

A/C Pressure Transducer Components and Components Location

Component Location ...

Other information:

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: High Voltage Shut-off Procedures


High Voltage Shut-off Procedures     Be sure to read and follow the “General Safety Information and Caution” before doing any work related with the high voltage system. Failure to follow the safety instructions may result in serious electrical injuries.     • High voltage components: ...

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Power Door Lock Actuators Repair procedures


Inspection Front Door Lock Actuator Inspection 1. Remove the front door trim. (Refer to the BD group - "Front door") 2. Remove the front door module. 3. Disconnect the 7P connector from the actuator. 4. Check actuator operation by connecting power and ground according to the table. To prevent damage ...

© 2021 Copyright www.koptimatfhev.com