Kia Optima Hybrid: Charging System / Auxiliary 12V Battery Description and Operation

Description
1.
The maintenance-free battery is, as the name implies, totally maintenance free and has no removable battery cell caps.
2.
Water never needs to be added to the maintenance-free battery.
3.
The battery is completely sealed, except for small vent holes in the cover.

   
After disconnecting then reconnecting the battery negative cable, reset some parts that require the reset procedures. (Refer to BE group - "General Information")
Auxiliary 12V Battery Components and Components Location

Components 1. Battery tray2. Auxiliary 12V Battery3. Battery upper bracket ...

Auxiliary 12V Battery Repair procedures

Removal and Installation 1. Disconnect the battery negative terminal (B) first, then the positive terminal (A). Tightening torque : (+) terminal (A) : 7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft) (-) ...

Other information:

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Intake Actuator Repair procedures


Inspection 1. Ignition "OFF". 2. Disconnect the intake actuator connector. 3. Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7. 4. Verify that the intake actuator operates to the fresh position when connecting in the reverse. ...

Kia Optima Hybrid (TF HEV) 2016-2020 Service Manual: Description and Operation


Description Ignition timing is controlled by the electronic control ignition timing system. The standard reference ignition timing data for the engine operating conditions are preprogrammed in the memory of the ECM (Engine Control Module). The engine operating conditions (speed, load, warm-up condition, ...

© 2022 Copyright www.koptimatfhev.com