Inspection |
1. |
Ignition "ON" |
2. |
Manually operate the control switch and measure the voltage of blower motor. |
3. |
Select the control switch to raise voltage until high speed.
|
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the main crash pad lower cover (A). |
3. |
Disconnect the PWM blower module connector (A) and then remove the PWM blower module (B) after loosening the mounting screws. |
4. |
Installation is the reverse order of removal. |
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation. ...
Description This has particle filter which eliminates foreign materials and odor. The particle filter includes odor filter as well as conventional dust filter to ensure comfortable interior environment. ...
Troubleshooting SymptomsPossible CausesRemedyWarning illuminated"Check active air flap system"Active Air Flap System Fail(Flap stuck)• Inspect the flap and remove the foreign substance• Check the Active Air Flap assembly • Repair or replace as requiredActuator FaultReplace the actuatorMalfunction ...
Description NVLD(Natural Vacuum Leakage Detection) is located between the canister and the fuel tank air filter. NVLD is to detect leaks equivalent to a 0.5 mm hole in the fuel tank, canister and hoses. When the engine has been running, the temperature of the fuel in the fuel tank is raised slightly. ...