Specifications |
Control Pressure kpa (kgf/cm?, psi) | 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) |
Current value (mA) | 50 ~ 850 |
Internal resistance (?) | 5.1 |
Description 26 brake control solenoid valve(26/B_VFS) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure to the 26 brake. ...
Circuit Diagram ...
Inspection 1. Connect the GDS on the Data Link Connector (DLC). 2. Measure the output voltage of the MAPS at idle and IG ON. Test ConditionOutput Voltage (V)IG ON3.9 ~ 4.1Idle0.8 ~ 1.6 Removal 1. Turn the ignition switch OFF and disconnect the battery negative (-) terminal. 2. Disconnect the manifold ...
Replacement 1. Discharge refrigerant from refrigeration system. 2. Replace faulty tube or hose. Cap the open fittings immediately to keep moisture or dirt out of the system. 3. Tighten joint of bolt or nut to specified torque. Connections should not be torque tighter than ...