| Specifications |
| Item | Specification |
| Rating voltage | DC 12V |
| Operating voltage | DC 9V ~ 16V |
| Operating temperature | -22°F ~ 176°F (-30°C ~ +80°C) |
| Maintaining temperature | -40°F ~ 185°F (-40°C ~ +85°C) |
| Max, humid | 95% |
| Consumption current | MAX 700mA |
| Dark current | Below 2mA |
| Item | Specification |
| Rating voltage | 13.5V (Slide, Recline, Front height, Rear height) |
| Current | Slide : 8A |
| Recline : 8A | |
| Front height : 7.5A | |
| Rear height : 7.5A | |
| At worst current | Slide : 24A |
| Recline : 20A | |
| Front height : 25A | |
| Rear height : 27A |
| Mechanical System |
| Item | Specification |
| Type | Motor with hall IC |
| Duty ratio | 50 ± 15 |
| Total stroke | Slide : 240mm |
| Recline : 63° | |
| Front height : 32mm (Motor) | |
| Rear height : 52mm (Motor) | |
| Total pulse number | Slide : 899 |
| Recline : 1,136 | |
| Front height : 332 | |
| Rear height : 412 | |
| Moving speed (Terminal voltage : 13.5V) | Slide (forward): 17.9mm or more Slide (backward): 20.2mm or more |
| Recline : 3.5 °/ sec | |
| Front height : 7mm / sec or more | |
| Rear height : 7mm / sec or more |
Components and Components LocationComponent Location 1. Seat Memory Unit (IMS)2. IMS control switch3. IMS driver power seat control ...
Inspection Diagnosis With GDS 1. It will be able to diagnose defects of power window with GDS quickly. GDS can operates actuator forcefully, input/output value monitoring and self diagnosis. 2. Select model and "BCM". 3. Select the "SJB" to check. 4. Select "Current data", if you will check current data ...
Removal 1. Turn the ignition switch OFF and disconnect the battery negative (-) terminal. 2. Release the residual pressure in fuel line (Refer to “Release Residual Pressure in Fuel Line” in this group). 3. Disconnect the injector connector (A). 4. Remove the wiring harness bracket mounting bolt (B). ...